Submitted by Anonymous (not verified) on Mon, 03/19/2001 - 00:00 Forums BlueSeries When doing an IPL, the BLUESERVER job fails to start during the IPL. Why? Re: When doing an IPL, the BLUESERVER job fails to start.. The cause to the problem is that BlueFax starts as an autojob from QCTL, but the TCP/IP subsystem is yet not started at this point. The solution (until we release a fix) is to: Restart the BlueFax subsystem after each IPL. You can use ADDJOBSCDE from the QSTRUP program. Log in or register to post comments Log in or register to post comments
Re: When doing an IPL, the BLUESERVER job fails to start.. The cause to the problem is that BlueFax starts as an autojob from QCTL, but the TCP/IP subsystem is yet not started at this point. The solution (until we release a fix) is to: Restart the BlueFax subsystem after each IPL. You can use ADDJOBSCDE from the QSTRUP program. Log in or register to post comments
Re: When doing an IPL, the BLUESERVER job fails to start..
The cause to the problem is that BlueFax starts as an autojob from QCTL,
but the TCP/IP subsystem is yet not started at this point.
The solution (until we release a fix) is to:
Restart the BlueFax subsystem after each IPL. You can use ADDJOBSCDE
from the QSTRUP program.